5-32
(15).
TM 9-2350-311-34-1
5-5 AIR CLEANER BLOWER MOTORS — CONTINUED
C. Assembly — Continued
9
10
11
12
Measure from motor cover (3) to end of impeller (22). Add or subtract washers as required to obtain 1.593-to
1.609-in. (4.046- to 4.087-cm) dimension.
Solder leads (19) to connect capacitor (20), assembling capacitor lead assembly (17).
Install new preformed packing (18), capacitor lead assembly (17), four new Iockwasher (16), and four screws
Install clip (14), ground lead (8), new Iockwasher
1.593 TO 1.609 IN.
(4.046 TO 4.087 CM)
(13), and screw (12) to impeller housing (39).