28 Loosen hose clamp (65).
29 Disconnect surge tank-to-coolant main tube hose (66) from coolant main tube (67).
30 Loosen two hose clamps (68).
31 Disconnect hose connector (69) from coolant pump (70).
32 Loosen two hose clamps (71) and remove two hoses (72) from two elbows (73) at crossover tube (74).
33 Remove two elbows (73) from crossover tube (74).
34 Loosen two hose clamps (75) at bypass thermostat housing (76).
35 Remove screw (77), Iockwasher (78), and clamp (79). Discard Iockwasher.
36 Pull coolant main tube-to-bypass thermostat housing connector hose (80) away from bypass thermostat
housing (76).